– 9860MT
IP9860MT provides remote manual control of the critical devices by clicking on a few buttons on the smart phone or computer webpage. Stop the problem device by cutting off the power to a specific outlet. By cycling the power off and restarting the device remotely, you save time and money by eliminating the need to send technicians to the root cause of the problem. Managers can monitor the total power usage information of PDU from the remote end through the Internet to fully understand the power consumption of all the devices. Set up overload event alerts and notify managers via Email and TRAP, allowing managers to respond to crises in the shortest possible time to minimize disasters. Provide central management software, which can manage a large number of PDUs' power, temperature and humidity information. The database stores the power consumption information of the power strip and provides the history curve chart for the manager's reference.
– Features
• Support HTTP, HTTPS/SSL, TCP/IP, PPPOE, DHCP, DDNS, SNMP v3, SMTP, NTP, TLS.
• Support Cloud Connect : AWS IOT, GOOGLE Cloud IoT, Microsoft AZURE IOT.
• Support Telnet/SSH.
Equipped with two Ethernet ports, IPPower9820MT can be accessed on two separate networks or VLANs. Auto failover to a 2nd Ethernet-connection in the event of network interruption,ensuring 100% iPDU uptime reporting. | Command your IPPower through a friendly web interface, via a curl, from a command line, or from your own application via an HTTP get post API(CGI). | ||
PING Ping function provides 2 IP with with AND OR logic combination. When the specified IP does not respond to PING, IPPower will perform a user-defined power action. The action can be select outlet on/off/power-cycle, shutdown on LAN/wake on LAN and email notification. | Schedule Task Scheduler allows you to schedule and run actions at pre-defined time table. There are 30 time table which are selected from web calendar of everyday,week or once. When the time up IPPower perform a user-defined power action. The action can be select outlet on/off/power-cycle,shutdown on LAN/wake on LAN and email notification. | ||
Ammeter Measure each power consumption to balancing circuits, preventing overloads and checking power failures. | Voltmeter Measure power voltage preventing overloads and checking power failures. | ||
rfc v1,v2,v3 available user can get MIB information from weppage Under SNMP protocol enviroment,user can control power on/off and power cycle, chaneg IP/Port |
User-definable power status on/off/last time | ||
In M2M mode, if you control IPPower-A, the other IPPower-B will do the same job. It is easy to monitor the remote sites |
Remote Control If enable CNT function, please download Andriod and ios APP and Nod-red software package to control and monitor |
||
VPN client mode IPPower can connect with a VPN router. It can be controlled and monitored at the same VPN |
Remote Control If enable SMTP function, If the status changed,IPPower will send notifications by email If enable POP3 function, IPPower can be controlled from email |
||
– Specification
Dimensions | 450 x 240 x 45mm( L / W / H ) |
Power input | 100~240VAC wiring or IEC309 max32A |
Maximum current per outlet | 10A |
Maximum current total 8 outlets | 32A |
Interface | 8 LED indicator lights Reset Breaker - Fuse protection button DI sensor IR Sensor HW Reset DC 12V Output LCD |
Operating temperature | 0~50°C |
Network | RJ-45 10/100Mb Ethernet port x 2 Host Port Lan Port |
USB | USB 2.0 Port |